Produttore chimico di alta qualità
Hotline nazionale di consultazione:+86 021-64208466

High boiling aromatic hydrocarbon solvent

1. Key Characteristics and PropertiesHigh boiling aromatic hydrocarbon solvents (boiling point

Email: info@standard-groups.com

Contenuto

1. Key Characteristics and Properties

High boiling aromatic hydrocarbon solvents (boiling point >200°C) are widely used in industrial applications due to their excellent solvency and thermal stability.

PropertyTypical RangeTest MethodSignificance
Boiling Point200-300°CASTM D86Determines evaporation rate
Punto Flash100-150°CASTM D93Safety handling consideration
Density (20°C)0.95-1.05 g/cm³ASTM D4052Affects formulation calculations
Viscosity (25°C)2-15 cPASTM D445Impacts flow characteristics
Aromatic Content≥98%ASTM D2360Solvency power indicator
Sulfur Content ≤10 ppmASTM D5454Environmental compliance


2. Common Applications by Industry

These solvents serve critical functions across multiple industries:

IndustryApplicazioneBenefitsTypical Formulations
CoatingsHigh-bake enamelsExcellent flow and leveling15-25% of total formulation
AdhesivesHot-melt adhesivesEnhanced thermal stability5-15% of resin system
ElectronicsPCB cleaningEffective flux removal80-100% pure solvent
RubberTire cord adhesivesImproved rubber-to-metal bonding10-20% of adhesive system
Printing InksGravure inksGood pigment wetting20-40% of ink vehicle


3. Safety and Handling Guidelines

Proper handling ensures safe use of these solvents:

AspectRequirementProtection MeasuresEmergency Procedures
StorageSteel drums (N2 blanket)Grounding of containersFoam extinguishers for fire
Personal ProtectionChemical gogglesRespirator (organic vapor)Eye wash station available
VentilationLEV system requiredExplosion-proof equipmentVapor detector alarms
Spill ManagementSecondary containmentAbsorbent materials readyEvacuate area for large spills
Waste DisposalHazardous waste classificationLicensed disposal contractorNever pour into drains


Key Recommendations:

For high-temperature applications: Select solvents with boiling points >250°C

In enclosed spaces: Implement vapor concentration monitoring

When replacing other solvents: Conduct compatibility testing

For environmental compliance: Verify local VOC regulations

These solvents offer superior performance for demanding applications when selected and handled appropriately. Their high solvency power and thermal stability make them indispensable in many industrial processes.

Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.